Constant Voltage Transformer - Cvt

Supplier : Elent Electronics Pvt. Ltd.

Key Features of Constant Voltage Transformer - Cvt
  • No semiconductors or moving parts used, hence very high reliability
  • No feedback control used
  • Intrinsic current limiting and short circuit protection
  • Output voltage correction within ? Cycle [10 ms] from no load to full load for specified load and line variation
  • Short term over load capability
  • Energy storage for line loss up to 3 ms at typical loads
  • Higher input voltage control range, for loads less than rated load
  • Very high line transient/spike rejection capability and excellent input to output isolation characteristics
  • Output floating [optional]
  • Input Voltage: 180V-260V [other choices on request]
  • Line Frequency: 50Hz
  • Output Voltage: 220/230 +/-1%
  • Output Step load response: 2 cycles [30 to 40 milliseconds]
  • Efficiency: 90% [approx] under full load conditions
  • Output Waveform: Sinusoidal
  • Waveform Distortion: 5% [approx] under full load conditions
  • Load Power Factor: 0.75% lag to 0.9% lead
  • Ambient Temperature: -5Degree C to 50Degree C
  • Transformer Type: Ferro-Resonant
  • Effect of Frequency: 1.6% [approx] change in output voltage for every 1% change in line frequency
Enquire now
Product Profile of Constant Voltage Transformer - Cvt
Elent Electronics Pvt. Ltd. manufactures Constant Voltage Transformer - CVT. Elent Electronics Pvt. Ltd. is an ISO 9001:2000 certified company that offers wide range of power conditioning equipment like On-line Uninterruptible Power Supplies, Off-line & Line Interactive UPS, Constant Voltage Transformers and Servo Voltage Transformers. The Constant Voltage Transformer - CVT find applications in Computers, Data Processing equipment, Colour Photography Labs., Bio-medical equipment, PA equipment, Telecommunication, TV, VCD/DVD recorders & players, Teleprinters, Fax machines and all other sensitive electronic devices.

Key Features of Constant Voltage Transformer - Cvt
  • No semiconductors or moving parts used, hence very high reliability
  • No feedback control used
  • Intrinsic current limiting and short circuit protection
  • Output voltage correction within ? Cycle [10 ms] from no load to full load for specified load and line variation
  • Short term over load capability
  • Energy storage for line loss up to 3 ms at typical loads
  • Higher input voltage control range, for loads less than rated load
  • Very high line transient/spike rejection capability and excellent input to output isolation characteristics
  • Output floating [optional]
  • Input Voltage: 180V-260V [other choices on request]
  • Line Frequency: 50Hz
  • Output Voltage: 220/230 +/-1%
  • Output Step load response: 2 cycles [30 to 40 milliseconds]
  • Efficiency: 90% [approx] under full load conditions
  • Output Waveform: Sinusoidal
  • Waveform Distortion: 5% [approx] under full load conditions
  • Load Power Factor: 0.75% lag to 0.9% lead
  • Ambient Temperature: -5Degree C to 50Degree C
  • Transformer Type: Ferro-Resonant
  • Effect of Frequency: 1.6% [approx] change in output voltage for every 1% change in line frequency
Product Specification of Constant Voltage Transformer - Cvt
  • Ambient Temperature: -5 to 50
  • Efficiency: ( Approx. ) 90%
  • Input Voltage: 180 - 260
  • Line Frequency: 50
  • Load Power Factor (PF): 0.75% lag to 0.9% lead
  • Output Voltage: 220/230 ±1%
  • Waveform distortion: ( Approx. ) 5%