Configuration Mode AMF Controller

Supplier : Bharani Electronics

Key Features of Configuration Mode AMF Controller
  • Rugged `Flush-mounted` Unit with Micro Controller technology.
  • Wide range of Auxiliary Supply: Unit operates between 06 VDC to 35 VDC ~ continuously variable
  • Withstands ?Cranking-Dropout? dip up to 0 VDC of Auxiliary Supply up to 01 second [maximum]
  • Continuous supervision of Mains [EB] & DG Breaker status, thus ensuring human & equipment safety.
  • Internal interlock for Mains & DG Breaker, with LED Indication of respective CB status, for fail safe operation.
  • Facility to `Select`: 12V or 24V Battery, with indication & supervision of `Selected` Battery Voltage status.
  • TWO spare Terminals for connecting External [Aux. Input] Faults.
  • LED Fault Annunciation for: Start fail, LLOP, High Engine Temp., Engine Fault, Low Battery, Aux. Faults 1 & 2.
  • Front Panel Keypad Switches provided for: `Auto`, `Manual`, `Accept`, `Manual ON/OFF` & ?Emergency STOP`.
  • Unit has TWO major Modes of Operation to viz.: ?Configuration Mode? and ?Run Mode?
Enquire now
Product Profile of Configuration Mode AMF Controller
Bharani Electronics manufactures Configuration Mode AMF Controller. The Configuration Mode AMF Controller is used to ?set? all functions & values, using front panel keypad switches [guided by ?configuration table? provided].

Bharani Electronics is the supplier of tap position indicators, micro controller version, custom-made microcontroller bases instruments, liquid level controllers, amp panels, electronic hooters, electronic buzzers, timers, alarm annunciators and electro mechanic annunciators.

Key Features of Configuration Mode AMF Controller
  • Rugged `Flush-mounted` Unit with Micro Controller technology.
  • Wide range of Auxiliary Supply: Unit operates between 06 VDC to 35 VDC ~ continuously variable
  • Withstands ?Cranking-Dropout? dip up to 0 VDC of Auxiliary Supply up to 01 second [maximum]
  • Continuous supervision of Mains [EB] & DG Breaker status, thus ensuring human & equipment safety.
  • Internal interlock for Mains & DG Breaker, with LED Indication of respective CB status, for fail safe operation.
  • Facility to `Select`: 12V or 24V Battery, with indication & supervision of `Selected` Battery Voltage status.
  • TWO spare Terminals for connecting External [Aux. Input] Faults.
  • LED Fault Annunciation for: Start fail, LLOP, High Engine Temp., Engine Fault, Low Battery, Aux. Faults 1 & 2.
  • Front Panel Keypad Switches provided for: `Auto`, `Manual`, `Accept`, `Manual ON/OFF` & ?Emergency STOP`.
  • Unit has TWO major Modes of Operation to viz.: ?Configuration Mode? and ?Run Mode?
Product Specification of Configuration Mode AMF Controller
  • Dimensions: Cutout : 150mm [Horiz] x 110mm [Verti] <br> Bezel : 165mm [Horiz] x 125mm [Verti] <br> Depth : 75mm
  • Humidity: Upto 95% RH
  • Operating Current: 40mA [max] at 12V Battery ?and? 25mA [max] at 24V Battery.
  • Operating Temperature: 0 to 70
  • Storage Temperature: 10 to 90