Noise Cut-off Transformer

Product Category : Transformers
Follow Product

Supplier : Neel Industrial Systems Pvt. Ltd.

Key Features of Noise Cut-off Transformer
  • Symmetrical characteristics allow noise attenuation from sides.
  • No need for extra filter circuits.
  • Can be used where different ground potential exists or the ground of the equipment cannot be earthed.
  • No impedance matching required.
  • Protect the Computers, CNC Machines and Telecommunications equipment from damage due to electrical noise, spikes etc.
  • If ground potential of system units are different from each other and are exposed to the effects of instability at high frequencies.
  • If ground of the equipment cannot be earthed.
  • When no slightest current leakage is permitted in the equipment. Especially for computers and CNC controls less than 100 micro Amps is only permitted.
  • To protect against strong lighting, impulse noise, bus short-circuit, accidental discharge of capacitors etc. When no slightest current leakage is permitted in the equipment.
  • When multiple Noise Cut-off transformers are used, the suppression effects increase in proportion. Therefore, the effects of cascading Noise Cutt-off Transformers are remarkable.
  • To shield large number of electronic equipment which individually also are producing different types of electrical noise at a common busbar typically CNC machines, Drives, Hardening equipment etc. The use of NCT, being bidirectional, prevents damage due to circulating noise interference within them.
Enquire now
Product Profile of Noise Cut-off Transformer
Neel Industrial Systems Pvt. Ltd. manufactures Noise Cut-Off Transformer. Neel Industrial Systems Pvt. Ltd. is an ISO 9001:2000 certified company. The Noise Cut-Off Transformer or Ultra Isolation Transformer cuts off noise, so the machine can perform with musical perfection. Switching of electrical utilities in Industrial & Commercial environment generates spikes up to 6000 Volts & high frequency power line Noises.

Key Features of Noise Cut-off Transformer
  • Symmetrical characteristics allow noise attenuation from sides.
  • No need for extra filter circuits.
  • Can be used where different ground potential exists or the ground of the equipment cannot be earthed.
  • No impedance matching required.
  • Protect the Computers, CNC Machines and Telecommunications equipment from damage due to electrical noise, spikes etc.
  • If ground potential of system units are different from each other and are exposed to the effects of instability at high frequencies.
  • If ground of the equipment cannot be earthed.
  • When no slightest current leakage is permitted in the equipment. Especially for computers and CNC controls less than 100 micro Amps is only permitted.
  • To protect against strong lighting, impulse noise, bus short-circuit, accidental discharge of capacitors etc. When no slightest current leakage is permitted in the equipment.
  • When multiple Noise Cut-off transformers are used, the suppression effects increase in proportion. Therefore, the effects of cascading Noise Cutt-off Transformers are remarkable.
  • To shield large number of electronic equipment which individually also are producing different types of electrical noise at a common busbar typically CNC machines, Drives, Hardening equipment etc. The use of NCT, being bidirectional, prevents damage due to circulating noise interference within them.
Product Specification of Noise Cut-off Transformer
  • Common Mode Attenuation: 120 (Single phase), Three phase -100 (Std), 120 (On request)
  • Connections: Delta / Star (3 phase)
  • Coupling Capacitance: 0.1(for 100dB), 0.05 (for 120dB)
  • Dielectric Strength: 2500 (for 60 s)
  • Input Voltage: 110/220 (Single phase), 415* (Three phase)
  • Leakage Current: < 20
  • Operating Power Factor: Lagging 0.75 - 0.75 (Leading)
  • Output Voltage: 110/220 (Single phase), 415 (Three phase)
  • Rating: 0.4, 1 (Single phase), 1, 2 (Three phase)
  • Regulation: 2 - 4 (100% change in current)
  • Resistance: > 1000