Run Mode AMF Controller

Supplier : Bharani Electronics

Key Features of Run Mode AMF Controller
  • Rugged ?Flush-mounted? Unit with Micro Controller technology.
  • Wide range of Auxiliary Supply: Unit operates between 06 VDC to 35 VDC to continuously variable
  • Withstands ?Cranking-Dropout? dip up to 0 VDC of Auxiliary Supply up to 01 second [maximum]
  • Continuous supervision of Mains [EB] & DG Breaker status, thus ensuring human & equipment safety.
  • Internal interlock for Mains & DG Breaker, with LED Indication of respective CB status, for fail safe operation.
  • Facility to `Select`: 12V or 24V Battery, with indication & supervision of ?Selected? Battery Voltage status.
  • TWO spare Terminals for connecting External [Aux. Input] Faults.
  • LED Fault Annunciation for: Start fail, LLOP, High Engine Temp., Engine Fault, Low Battery, Aux. Faults 1 & 2.
  • Front Panel Keypad Switches provided for: ?Auto?, `Manual`, `Accept`, ?Manual ON/OFF? & ?Emergency STOP`.
  • Unit has TWO major Modes of Operation to viz.: ?Configuration Mode? and ?Run Mode?
Enquire now
Product Profile of Run Mode AMF Controller
Bharani Electronics is manufacturing Run Mode AMF Controller. The Run Mode AMF Controller can operate in either `Manual` or `Auto` modes, by pressing respective Front Panel Keypad provided. When in normal `Run mode` all "Function" & "Value" LEDs are `OFF` [if `Auto` in mode, its LED shall be ON]. In either of the Modes, all Functional & related Interlock parameters are inherent, for fail safe operation.

Bharani Electronics supplies micro controller version, custom-made microcontroller bases instruments, tap position indicators, liquid level controllers, amp panels, electronic hooters, electronic buzzers, timers, electro mechanic annunciators and alarm annunciators.

Key Features of Run Mode AMF Controller
  • Rugged ?Flush-mounted? Unit with Micro Controller technology.
  • Wide range of Auxiliary Supply: Unit operates between 06 VDC to 35 VDC to continuously variable
  • Withstands ?Cranking-Dropout? dip up to 0 VDC of Auxiliary Supply up to 01 second [maximum]
  • Continuous supervision of Mains [EB] & DG Breaker status, thus ensuring human & equipment safety.
  • Internal interlock for Mains & DG Breaker, with LED Indication of respective CB status, for fail safe operation.
  • Facility to `Select`: 12V or 24V Battery, with indication & supervision of ?Selected? Battery Voltage status.
  • TWO spare Terminals for connecting External [Aux. Input] Faults.
  • LED Fault Annunciation for: Start fail, LLOP, High Engine Temp., Engine Fault, Low Battery, Aux. Faults 1 & 2.
  • Front Panel Keypad Switches provided for: ?Auto?, `Manual`, `Accept`, ?Manual ON/OFF? & ?Emergency STOP`.
  • Unit has TWO major Modes of Operation to viz.: ?Configuration Mode? and ?Run Mode?
Product Specification of Run Mode AMF Controller
  • Dimensions: Cutout : 150mm [Horiz] x 110mm [Verti] <br> Bezel : 165mm [Horiz] x 125mm [Verti] <br> Depth : 75mm
  • Humidity: Upto 95% RH
  • Operating Current: 40mA [max] at 12V Battery ?and? 25mA [max] at 24V Battery.
  • Operating Temperature: 0 to 70
  • Storage Temperature: 10 to 90