The salient features of the Self Tune PID Temperature Controller with Soak Timer are as follows:
  • Programmable Thermocouples / RTD Pt100 Input
  • In-built Programmable Timer with Front / Remote Start
  • Selectable Relay / SSR Control Output [No Jumpers]
  • Self Tune PID Control with Overshoot Inhibit Feature
  • Auxiliary Control Output for Alarm or Blower / Compressor Control with Time Delay
  • Programmable Heat / Cool Control Modes
  • Optional Serial Communication Port
  • Size [mm]: 48[H] X 48[W] X 110[D]

  • Technical specifications of the Self Tune PID Temperature Controller with Soak Timer are as follows:
  • The Display user interface is 2 Rows of 4 digits, 7 Segment High Intensity LED, Upper Row: Process Value in Red, Lower Row: Set point Value / % Power in Green; Keyboard - 4 Front Panel Keys, Highly Simplified Operation
  • Input type - User Selectable Through Front Panel Keys, Thermocouple J, K, R, S, T, B, N, RTD Pt100 3-wire, DIN 43760; Accuracy - ± 0.25% of reading, ± 1 LSD, ± 1degreeC; Measuring Rate - 5 Samples per second [sampling time 200mS]; Corrections - Automatic, CJC for T / C, LRC for 3-wire Pt100.
  • Outputs 1 - For Control, User Selectable thru` Jumper Settings; Relay: 5A/230VAC or 5A/30VDC, Resistive; SSR Drive : 5VDC @ 40mA [non-isolated]; Output 2 - For Alarm or Auxiliary Control - Relay: 5A/230VAC or 5A/30VDC, Resistive, SSR Drive : 5VDC @ 40mA [non-isolated]
  • Additional features include Timer - Usable as Free Running, Batch or Soak Timer, User Settable Units & Ranges, Programmable Band for Soak Time Application, Power-Fail Time Retention & Recovery, Front / Remote Start; Control Action - Programmable as PID or On-Off; Control Mode - Programmable as Direct [Cool] or Reverse [Heat]; Tuning - X-THERM Self-Tune Algorithm for Automatic Setting of Basic P, I, D Values, Overshoot Inhibit Feature - Provided [PID Control only] with Enable / Disable & Settable Control Factor; Alarms - Two Soft Alarms [Assignable to Output 2 & Output 3], Settable Alarm Type [High, Low, Deviation, Window], Settable Hysteresis & Logic [Direct, Reverse]; Communication Port [Optional] - Serial, 2-wire, Half Duplex, RS485, Slave Mode, Settable Baud [4800, 9600, 19200, 38400, 57600], ID [1 to 127], Parity [None, Even, Odd], Start-stop synchronized MODBUS RTU Protocol
  • Supply Voltage - 85 to 264V AC, 50 / 60 Hz; Environmental - Operating 0 to 55°C, Storage -10 to 70°C, 5 to 95 %RH Non-condensing; Panel Sealing - Conforming to IP 65, NEMA 4X; Electromagnetic - Conforming to Generic Emissions standard EN50081-2 and general immunity requirements of EN50082-2 [95]; Safety Standard - Conforming to EN61010, installation category 2 [Voltage transients must not exceed 2.5 KV]; Dimensions [mm] - 48 [H] X 48 [W] X 110 [D]; Panel Cutout [mm] - 45 [H] X 45 [W], Weight [Approx] - 250 grams